Air compressor issue

Archived from the Tools In Action forum (In The Shop). This thread is read-only.

lemans63Member since Feb 2016

I am using this forum because I do not know if it belongs in another area but here goes.

I have a  Rand 4000 compressor that I have had for maybe 12 years. It has a 3.3 hp motor, 20 gal storage and 10 cfm @40 psi.  The problem is that it is not storing air in the tank.  The gauge reads 0 even after the unit has been running for 5 minutes.  The motor runs fine and the piston seems to be working just fine but no air in the tank.  Anyone have an idea where the problem might be?  Hate to buy a new one if this one can be repaired.  It has never given me any problems until now.  Any thoughts?  Thanks

JimboS1iceMember since Sep 2015

Welcome to the forum, does it sound like it’s leaking air or is the motor not compressing the air?

Jimbo

Sent from my iPhone using Tapatalk

comp56Member since Sep 2014

lemans63 wrote:

I am using this forum because I do not know if it belongs in another area but here goes.

I have a  Rand 4000 compressor that I have had for maybe 12 years. It has a 3.3 hp motor, 20 gal storage and 10 cfm @40 psi.  The problem is that it is not storing air in the tank.  The gauge reads 0 even after the unit has been running for 5 minutes.  The motor runs fine and the piston seems to be working just fine but no air in the tank.  Anyone have an idea where the problem might be?  Hate to buy a new one if this one can be repaired.  It has never given me any problems until now.  Any thoughts?  Thanks

all seals still sealing, head gasket per say, does it have water in it?…….can you hear any air coming out as it is turned on?

comp56Member since Sep 2014

and welcome to the forums….

MillerzconstructionMember since Dec 2015

Tank check valve maybe? They go bad a lot.

Millerz

MillerzconstructionMember since Dec 2015

Or the intake valve may need replaced?

Millerz

JMGMember since Dec 2015

I read somewhere that the Rand 4000 was manufactured by DeVilbiss. Looking at parts diagrams of their portable units, with your description, gives me the impression that your unit uses reed valves, as opposed to stem valves. It is highly probable that the reed plate has failed and needs to be replaced. In any event, from your description of the problem, you will probably need to disassemble the head to troubleshoot the problem. It could be as simple as a bad O ring, or possibly a jammed check-valve, but most likely a reed has cracked in the valve assembly.

 

Good-luck.

KnarlyCarlMember since Jan 2016

Hey man, welcome to the forum. I’ve worked on a lot of different compressors for several years now before switching positions at work, would love to get this up and running for you again.

Does it have a bleed off valve that lets air out whenever the compressor shuts down (like a hissing sound when it shuts off when it was working properly)?

If nothing is obvious, take the head off and start investigating

LoganMember since Jun 2015

Maybe the drain value is open or even the gauge could be broken

lemans63Member since Feb 2016

Logan p wrote:

Maybe the drain value is open or even the gauge could be broken.

I will check the drain valve.  I don’t think it is the gauge.  The unit would still stop once it reaches 100 psi.

 

lemans63Member since Feb 2016

KnarlyCarl wrote:

Hey man, welcome to the forum. I’ve worked on a lot of different compressors for several years now before switching positions at work, would love to get this up and running for you again.

Does it have a bleed off valve that lets air out whenever the compressor shuts down (like a hissing sound when it shuts off when it was working properly)?

If nothing is obvious, take the head off and start investigating

yes but nothing now.  I will start investigating.  Thanks for your reply.

lemans63Member since Feb 2016

JMG wrote:

I read somewhere that the Rand 4000 was manufactured by DeVilbiss. Looking at parts diagrams of their portable units, with your description, gives me the impression that your unit uses reed valves, as opposed to stem valves. It is highly probable that the reed plate has failed and needs to be replaced. In any event, from your description of the problem, you will probably need to disassemble the head to troubleshoot the problem. It could be as simple as a bad O ring, or possibly a jammed check-valve, but most likely a reed has cracked in the valve assembly.

 

Good-luck.

Thanks for your comments!  I will look into all of your suggestions.

lemans63Member since Feb 2016

JMG wrote:

I read somewhere that the Rand 4000 was manufactured by DeVilbiss. Looking at parts diagrams of their portable units, with your description, gives me the impression that your unit uses reed valves, as opposed to stem valves. It is highly probable that the reed plate has failed and needs to be replaced. In any event, from your description of the problem, you will probably need to disassemble the head to troubleshoot the problem. It could be as simple as a bad O ring, or possibly a jammed check-valve, but most likely a reed has cracked in the valve assembly.

 

Good-luck.

 

comp56 wrote:

all seals still sealing, head gasket per say, does it have water in it?…….can you hear any air coming out as it is turned on?

no water in it.  I do not feel or hear any air leaking someplace so perhaps it is an o ring issue.

lemans63Member since Feb 2016

Jimbos1ice wrote:

Welcome to the forum, does it sound like it’s leaking air or is the motor not compressing the air?

Jimbo

Sent from my iPhone using Tapatalk

I would say the motor is not compressing the air because I do not hear or feel any air coming from the unit.

JimboS1iceMember since Sep 2015

That doesn’t sound very good, maybe a bad gasket or some form of seal would be my guess, any odd noises?

Jimbo

Sent from my iPhone using Tapatalk

99_XC600Member since Jun 2015

It’s a valve issue in the head that a couple of members have already mentioned.

lemans63Member since Feb 2016

99_XC600 wrote:

It’s a valve issue in the head that a couple of members have already mentioned.

Thanks for the info.  I definitely will look into the valve probability.